Case study overview
Year
2019 – 2021
Product
thermally sprayed zinc anode, MC-DUR KKS Primer LM, MC-DUR LF KKS, welding membrane, cast asphalt
Location
Melsungen
Contracting Company
Fritz Wiedemann & Sohn GmbH
Technology
Thermal spraying of zinc wire
B. Braun Melsungen parking garage
Corrosion protection solution
Throughout the entire project, the participants underwent thorough training in cathodic corrosion protection techniques. In particular, the thermal spraying of zinc, a key component of the renovation, was closely monitored. The introduction of a monitoring system ensured constant monitoring and adjustment of corrosion protection. This multidisciplinary approach provided a robust, sustainable, and effective corrosion protection for the parking deck.


Downloads

Reference report “Parking garage, Melsungen”
Unique renovation in the Melsungen parking garage.

Factsheet “KKS-Beton”
Find out more about the corrosion protection of the future.